S4 Shock & Vibration Sensor
Piezoelectric Accelerometer: ± 100g
Digital Capacitive Accelerometer: ± 40g
Battery: 250 mAh
Storage: 8 GB
S4-E100D40
Why enDAQ?
Demo with an Engineer
Visit our Help Center
Customer Testimonials
Contact Customer Success
The S4-E100D40 is a vibration and shock recorder with a high performance piezoelectric accelerometer, a secondary capacitive accelerometer and other environmental sensors. This model is most popular for general purpose testing because of its wide application range. Its aluminum enclosure improves reliability in harsh environments and widens its frequency response.
Complimentary enDAQ Pelican case included with every enDAQ® sensor order.
Additional cases can be purchased here: enDAQ Accessories
Develop a Shock, Vibration and Environment Profile with ease & confidence for your specific application!
Take a deep dive of our applications pages for specific application resources.
- Vibration Sensing & Recording
- Shock & Impact Testing
- Shipping & Transport Monitoring
- Wi-Fi Enabled Wireless Monitoring
- Environmental Testing
Convenient |
|
---|---|
Adaptable |
|
Reliable |
|
Accelerometer Type | Range | Sampling Rate | Bandwidth | Noise | Resolution |
Piezoelectric | ± 100g | 20,000 Hz | 5 to 2,000 Hz | < 0.04 gRMS | 0.003 g |
Digital Capacitive | ± 40g | 4,000 Hz | 0 to 300 Hz | < 0.01 gRMS | 0.00008 g |
Please note: Piezoelectric accelerometers are susceptible to saturation due to exposure to high frequency events because they are AC coupled. If your application will have high frequency events (events with pulse widths less than 1 ms) we recommend checking out our S-R series products.
Find out more in our Piezoelectric Accelerometers Blog Post
Sensor | Measurement Range | Resolution | Sampling Rate |
Gyroscope | 2000°/s | 0.06 °/s | 0 (off) to 200 Hz |
Magnetometer | ± 1300 µT | 0.3 µT | 0 (off) to 10 Hz |
Temperature | -40 to 85 °C | 0.01 °C | 0 (off) to 10 Hz |
Pressure | 1 to 200 kPa | 1.6 Pa | 0 (off) to 10 Hz |
Humidity | 0 to 100 %RH | 0.04% RH | 0 (off) to 10 Hz |
Light | 0 to > 20 uV | <100 mlx | 0 (off) to 4 Hz |
Parameter | Range | Notes |
Operating Temperature | -10°C to 80°C (14°F to 176°F) | |
Recommended Storage Temperature | 15°C to 30°C (59°F to 86°F) | Recharging Temperature 0°C to 45°C (32°F to 113°F) |
Humidity | 0 to 95 %RH | Non-Condensing |
Pressure | 20 kPa to 110 kPa (2.9 psi to 16.0 psi) | Absolute Pressure |
Shock Limit | >3,000 g | Refer to Shock Report (PDF) |
No Electric Field Susceptibility | 2 MHz to 18 GHz @ 200 V/m | Refer to EMI Test Report (PDF) |
No Magnetic Field Susceptibility | 30 Hz to 100 kHz | Refer to EMI Test Report (PDF) |
Sample Rate | Storage Capacity | Continuous Recording | Main Accel. Trigger | 2nd Accel. Trigger | Periodic/Time Trigger |
100 Hz | 22 days | 13 hours | 13 hours | 52 hours | 52 days |
1,000 Hz | 9 days | 12 hours | 13 hours | 52 hours | 49 days |
5,000 Hz | 63 hours | 9 hours | 13 hours | 52 hours | 38 days |
20,000 Hz | 17 hours | 5 hours | 13 hours | 49 hours | 20 days |
Mass | 65 grams |
Case Material | Aluminum 7075 |
Mounting - Screw | 4-40 Bolts (100 in-oz) |
Mounting - Tape (Double Sided) | 3M 950 Tape |
Length | 76.2 mm (3.00") |
Width | 29.8 mm (1.18") |
Thickness | 18.3 mm (0.72") |
Ingress Protection | IP 50 (Dust Protected) |
- Convenient - Intuitive Operation and Sensors that Can Go Anywhere Learn More
- Adaptable - Selectable Sensor Packages and Configurable Settings and Software Learn More
- Reliable - Every Device is Calibrated and Made in the USA to Ensure Quality Learn More