Why enDAQ?
Demo with an Engineer
Visit our Help Center
Customer Testimonials
Contact Customer Success
The Slam Stick X is a shock recorder with a high performance piezoresistive accelerometer, a secondary capacitive accelerometer and other environmental sensors. This model is most popular for shock testing. Its aluminum enclosure improves reliability in harsh environments and widens its frequency response.
It has been discontinued and replaced by the S4-R500D40. There are also many other new and updated products you can compare on our sensors page. If you have any questions, we're here to help!
Complimentary enDAQ Pelican case included with every enDAQ® sensor order.
Additional cases can be purchased here: enDAQ Accessories
Convenient |
|
---|---|
Adaptable |
|
Reliable |
|
Accelerometer Type | Range | Sampling Rate | Bandwidth | Noise | Resolution |
Piezoresistive | ± 500g | 20,000 Hz | 0 to 2,000 Hz | < 0.40 gRMS | 0.015 g |
Digital Capacitive | ± 16g | 3,200 Hz | 0 to 300 Hz | < 0.01 gRMS | 0.004 g |
Sensor | Measurement Range | Resolution | Sampling Rate |
Gyroscope | 2000°/s | 0.06 °/s | 0 (off) to 200 Hz |
Magnetometer | ± 1300 µT | 0.3 µT | 0 (off) to 10 Hz |
Temperature | -40 to 85 °C | 0.01 °C | 0 (off) to 10 Hz |
Pressure | 1 to 200 kPa | 1.6 Pa | 0 (off) to 10 Hz |
Humidity | 0 to 100 %RH | 0.04% RH | 0 (off) to 10 Hz |
Light | 0 to > 20 uV | <100 mlx | 0 (off) to 4 Hz |
Parameter | Range | Notes |
Operating Temperature | -10°C to 80°C (14°F to 176°F) | |
Recommended Storage Temperature | 15°C to 30°C (59°F to 86°F) | Recharging Temperature 0°C to 45°C (32°F to 113°F) |
Humidity | 0 to 95 %RH | Non-Condensing |
Pressure | 20 kPa to 110 kPa (2.9 psi to 16.0 psi) | Absolute Pressure |
Shock Limit | >3,000 g | Refer to Shock Report (PDF) |
No Electric Field Susceptibility | 2 MHz to 18 GHz @ 200 V/m | Refer to EMI Test Report (PDF) |
No Magnetic Field Susceptibility | 30 Hz to 100 kHz | Refer to EMI Test Report (PDF) |
Sample Rate | Storage Capacity | Continuous Recording | Main Accel. Trigger | 2nd Accel. Trigger | Periodic/Time Trigger |
100 Hz | 22 days | 11 hours | 17 hours | 64 hours | 45 days |
1,000 Hz | 9 days | 11 hours | 17 hours | 64 hours | 43 days |
5,000 Hz | 63 hours | 9 hours | 16 hours | 63 hours | 36 days |
20,000 Hz | 17 hours | 5 hours | 16 hours | 60 hours | 22 days |
Mass | 65 grams |
Case Material | Aluminum 7075 |
Mounting - Screw | 4-40 Bolts (100 in-oz) |
Mounting - Tape (Double Sided) | 3M 950 Tape |
Length | 76.2 mm (3.00") |
Width | 29.8 mm (1.18") |
Thickness | 18.3 mm (0.72") |
Ingress Protection | IP 50 (Dust Protected) |